Skip to content

Roof Sheathing Thickness: Span Ratings, H-Clips and Code Basics

By Updated 2 min read

Line drawing illustrating roof sheathing thickness

Quick answer

Most residential roofs use 7/16 inch OSB or 1/2 inch (15/32) plywood. The rule is that the panel's span rating must meet or exceed the rafter spacing: a 24/16 panel is good for supports up to 24 inches apart. For 24 inch spacing, heavy snow or tile roofs, step up to 5/8 inch (19/32) or add H-clips as the panel requires.

Most common
7/16 in OSB
Tile / heavy snow
5/8 in
Rule
Span ≥ spacing

Roof sheathing thickness is not a style choice. It is decided by three things: how far apart your rafters are, how much load the roof carries and what the panel’s span rating allows. Here is how to get it right.

Span rating is the rule

Every structural panel is stamped with a span rating such as 24/16. For roofs, the first number is the maximum distance between supports in inches. Pick a panel whose first number is at least your rafter or truss spacing.

Common panel Typical span rating Roof support spacing
3/8 in 24/0 Up to 24 in, with edge support, light loads
7/16 in OSB 24/16 Up to 24 in
15/32 or 1/2 in 32/16 Up to 32 in
19/32 or 5/8 in 40/20 Up to 40 in
23/32 or 3/4 in 48/24 Up to 48 in

These are typical ratings. Read the stamp on the actual panel, because ratings vary by product and mill.

When to go thicker

  • 24 inch truss spacing and you want a flat deck without clips: 19/32 (5/8) inch.
  • Heavy snow loads: check the code tables for your ground snow load. Thicker panels or closer spacing may be required.
  • Tile or slate roofs: these heavy materials are commonly installed over 5/8 inch or thicker decking. Follow the tile maker’s specs.
  • Walkability and feel: thicker decking feels less springy to roofers and resists “picture framing” (visible rafter lines through shingles).

H-clips and edge support

H-clips are small metal clips that slide onto panel edges between rafters. They:

  • Support the unsupported long edges of the panels
  • Keep the recommended 1/8 inch gap between panels so they can expand
  • Are required when the panel and code call for edge support at your spacing

Typically you use one clip per span between rafters at 24 inches on center, and two per span on wider spacing. Solid wood blocking between rafters is an alternative.

Gaps and orientation

  • Install panels with the long dimension across the rafters.
  • Stagger the end joints by at least one rafter bay.
  • Leave about 1/8 inch between panel edges and ends (unless the manufacturer says otherwise).
  • Panel ends should land on the center of a rafter.

How much sheathing do you need?

Divide roof area by 32 sq ft per sheet and add about 10% for cuts. A 40 × 30 ft house with a 12 inch overhang at 6/12 has 1,503 sq ft of roof, so about 52 sheets. Run your own numbers with the roof square footage calculator.

Choosing between materials? Read OSB vs plywood for roof sheathing. Need the quick size answer? See what size plywood for a roof. For the fastening schedule, see roof sheathing nails and spacing.

Frequently asked questions

What is roof sheathing?

Roof sheathing, or roof decking, is the layer of structural panels (plywood or OSB) nailed over the rafters or trusses. It carries the roof loads to the framing and gives the underlayment and shingles a solid base.

Should I use 1/2 or 5/8 plywood for my roof?

1/2 inch (15/32) works for most roofs with supports up to 24 inches apart when used with H-clips or as the span rating allows. Choose 5/8 inch (19/32) for 24 inch spacing without clips, heavy snow loads, tile or slate, or when you want a stiffer, flatter deck.

Are H-clips required on roof sheathing?

They are required when the panel's span rating and the code call for edge support at your rafter spacing, most often with thinner panels on 24 inch spacing. H-clips also keep the 1/8 inch expansion gap consistent. Blocking can be used instead.

Is 7/16 OSB OK for a roof?

Yes, 7/16 inch OSB rated 24/16 is widely used on roofs with rafters or trusses up to 24 inches on center, with edge support as required. It is a common default for new homes.

Figures are typical US values for planning. Building codes, product specs and local prices vary, so confirm with your local code office, the product's installation guide and a licensed roofer. See how we write and check our guides.